General
Specefication
|
Heating |
Forced Air Convection |
|
Refrigeration |
CFC Free air cooled hermetically
sealed compressor |
|
Temp.
Range |
ambient +5 oC ~
70 oC [ JSMI-02T ] +0 oC ~ 70 oC
[ JSMI-02C, 02CP, 02CPL ] |
|
Accuracy |
± 0.2 oC |
|
Uniformity |
± 1.0 oC |
|
Controller |
JIC-CON 5th Generation Digital
PID Temperature Controller |
|
|
10 Step Temperature Programming
Capability, 1 ~ 999 times repeatable [ JSMI-02CP, CPL ] |
|
|
Light ON/OFF Program on each
program step for Day-Night simulation [ JSMI-02CPL ] |
|
|
3 Group Zone PID Temperature
Control Algorithm |
|
|
3-Point Temperature Calibration |
|
|
1-Point Temperature Offset
Calibration |
|
Sensor |
Class A Pt-100 Ω Sensor |
|
Safety |
Over-Temperature Cut-Off |
|
|
Over-Cooling Cut-Off |
|
|
Over Current Cut-Off |
|
Material |
Body - Epoxy Powder Coated Steel |
|
|
Chamber – Stainless Steel 304 |
|
|
Inner Door – 5 mm thick Tempered
Safety Glass |
|
|
including PVC coated wire shelf |
|
|
optional perforated stainless
steel shelf |
|
Electrical Data |
220±10% VAC 50/60Hz 1-Phase |
|
Plug config. |
CEE 7/7 Schuko or BS 1363 |
Future
10 Step Temperature and
Day/Night PROGRAM
User can compose 10 steps of varying
temperature and light
ON/OFF program and can save it in a
memory.
Composed program can be repeated 1 ~
999 times
or unlimited number of time.
|
Performance |
|
• Control Temperature Range JSMI-02T from ambient
+5℃ to +70℃ JSMI-02C, 02CP,
02CPL from +0℃ to +70℃ • Forced air circulation for
excellent thermal accuracy and uniformity • Aero-dynamic chamber
designed with circulation blower to achieve superior thermal uniformity • Separate heating
compartment located on back wall for contamination free and maintenance free • Air cooled refrigeration
system with hermetically sealed compressor |
|
Controller |
|
• DIGITAL MICROPROCESSOR PID
TEMPERATURE CONTROLLER Integrated
Digital Microprocessor Control System • GRAPHIC LCD DISPLAY Back Light
Graphic LCD Display provides user-friendly operating information • UV COATED POLYCARBONATE
TOUCH PANEL Equipped with
Capacitive LED Lighting Touch Button provides sensitive touching operation
and durability • ENCODER TYPE JOG DIAL Push to Start
and Stop, Rotary turn to change values provides easy and simple user
interface • 0.1 oC
CONTROL RESOLUTION • 10 Step Programming
Capability, 1 ~ 999 times repeatable [ JSMI-02CP, 02CPL only ] • Light ON/OFF Program on
each program step for Day-Night simulation [ JSMI-02CPL only ] • Auto-Stop
Timer 1 min ~ 99 hour 59 min and alarm • Auto-Start Timer 1
min ~ 99 hour 59 min and alarm • Temperature and Timer
Memory Function in frequent use • 3-ZONE PID ALGORITHM • 3-POINT CALIBRATION /
1-POINT OFFSET CALIBRATION • POWER and TIMER RESTORE
FUNCTION in case electric power outage • CLASS A PT-100 Ω Sensor • Delay starter to protect
compressor. • RS-232C PC COMMUNICATION
INTERFACE [OPTION] |
|
Construction |
|
• Durable epoxy powder
coated metallic casing • Corrosion resistant
Stainless Steel 304 chamber with seamless round cornered edge allows easy
cleaning and prevent leakage • Tempered safety inner
glass door for easy observation of samples |
|
Convenience |
|
• Outer door with
self-adhesive magnetic packing • Inner glass door with high
density silicone gasket and air-tight door lock • Removable and height
adjustable shelf by 25mm spacing |
|
Safety |
|
• PT SENSOR SHORT OR
DISCONNECTION AUDIO VISUAL ALARM • DUAL OVER TEMPERATURE
CUT-OFF BY CONTROLLER AND INDEPENDENT THERMOSTAT Controller
cut-off heater, compressor and AUDIO VISUAL ALARMS ALARM HIGH :
+5 oC above set temp. ALARM LOW :
-5 oC below set temp. Independent
analog thermostat cut-off heater above set temperature • DOOR OPEN AUDIO VISUAL
ALARM • OVER CURRENT CUT-OFF :
Electric Circuit Breaker |
MODEL
|
||||
|
Dimension Data |
|
|
|
|
|
Chamber Volume |
2
chamber x 125 L |
← |
← |
← |
|
Inner Dims. (W x D x H mm) |
500
x 500 x 500 |
← |
← |
← |
|
Outer Dims. (W x D x H mm) |
680
x 825 x 1530 |
680
x 825 x 1820 |
← |
680
x 850 x 1820 |
|
No. of Shelf Positions |
16
ea |
← |
← |
← |
|
No. of Shelf included |
4
ea |
← |
← |
← |
|
|
|
|
|
|
|
Performance Data |
|
|
|
|
|
Heating System |
Forced
Air Convection |
|||
|
Cooling System |
none |
Compressor |
← |
← |
|
Temp.
Range |
amb.+5
oC ~ +70 oC |
+0
oC ~ +70 oC |
← |
← |
|
Accuracy at +20.0 oC |
±0.2
oC at +37.0 oC |
±0.2
oC at +20.0 oC |
← |
← |
|
Uniformity at +20.0 oC |
±1.0
oC at +37.0 oC |
±1.0
oC at +20.0 oC |
← |
← |
|
Lamp Type, Length |
none |
none |
none |
LED
300 mm |
|
Lamp Configuration |
none |
none |
none |
5 watt x 5 ea |
|
|
|
|
|
|
|
Controller |
|
|
|
|
|
Processor |
Digital Microprocessor PID
Temperature Controller |
|||
|
10 Step Temperature Program |
n/a |
n/a |
yes |
yes |
|
Light ON/OFF Program |
n/a |
n/a |
n/a |
yes |
|
|
|
|
|
|
|
Electrical Data |
|
|
|
|
|
Rated voltage |
220 ± 10% VAC |
← |
← |
← |
|
Power frequency |
50 / 60Hz |
← |
← |
← |
|
Heater Output |
2 x 200 W |
2 x 1.0 kW |
← |
← |
|
Nominal power |
400 W 2.0 amp |
3.2 kW 14.5 amp |
← |
← |
|
Phase |
1 Phase |
← |
← |
← |
|
Plug configuration |
CEE 7/7 Schuko or BS 1363 |
|||