Key Features
  • JSDS-Series Temperature and Humidity Drug Stability Chamber designed for Drug Stability Test for pharmaceutical industry meets the requirement of ICH Guideline Q1A (Stability Test)
  • Chamber Volume (Capacity): 432 Liters
  • Inner Dims. (W x D x H) 600 x 600 x 1200 mm
  • Outer Dims. (W x D x H) 790 x 935 x 1985 mm
  • No. of Shelves: included 3 EA
  • No. of Shelf: position 35 EA by 25 mm spacing
  • Heating: Forced Air Convection
  • Cooling CFC Free air cooled compressor
  • View More Info
1,150,000৳

Description :

Drug Stability Chamber Chamber Volume: 432 Liters Temp. Range: +10℃ ~ +70℃  Model: JSDS-420C JSR South Korea


JSDS-Series Temperature and Humidity Drug Stability Chamber designed for Drug Stability Test for pharmaceutical industry meets the requirement of ICH Guideline Q1A (Stability Test)


Specification: 

Chamber Volume (Capacity): 432 Liters

Inner Dims. (W x D x H) 600 x 600 x 1200 mm

Outer Dims. (W x D x H) 790 x 935 x 1985 mm

No. of Shelves: included 3 EA

No. of Shelf: position 35 EA by 25 mm spacing

Heating: Forced Air Convection

Cooling CFC Free air cooled compressor

Control: Program Mode 1 Patterns Memory 11 Segments

Manual Mode Fixed Temp. operation with timer

Temp. Range +10℃ ~ +70℃

Accuracy ±0.3℃ at +20℃, 60% RH

Uniformity ±1.0℃ at +20℃, 60% RH

Sensor Class A PT-100 Ω Sensor

Humidity Range 30% ~ 85% RH

Accuracy ±3.0% at 60% RH

Uniformity ±6.0% at 60% RH

Sensor: Electronic Humiral Sensor

Lamp: configuration 3 ea x 36 Watt fluorescent tube

Safety Over-Temperature Cut-Off

Low water level Cut-Off

Over Current Cut-Off

Material Body : Epoxy Powder Coated Steel

Chamber : Stainless Steel 304

Electrical Requirement: 220 ± 10% VAC, 50/60Hz, 1-Phase

Heater Capacity 3.5 kW

Power Rating 21 amps

Plug Configuration 30 AMP Plug