Hotline : +8801325065151
Price: | 0৳ |
Status : | Call For Price |
Brand: | WTW Germany |
UV-VIS spectral sensors for nitrate, COD, BOD and TSS (optional), SKU: 481052, NiCaVis® 705 IQ - WTW Germany
Model | NiCaVis® 705 IQ | NiCaVis® 705 IQ TS | |
Order No. | 481052 | 481053 | |
* The UVT-254 value is standardized to 10 mm gap width. | |||
Measuring method | Spectral Measurement in the UV-VIS Range (200 – 720 nm) | ||
Measuring gap | 5 mm | ||
Application (optimized for) | Municipal wastewater: | Municipal wastewater: | |
Measuring range and Resolution | Effluent: | Effluent: | |
NO3 | 0.0 ... 250.0 mg/l 0.1 mg/l | 0.0 ... 250.0 mg/l 0.1 mg/l | |
NO3-N | 0.00 ... 50.00 mg/l 0.01 mg/l | 0.00 ... 50.00 mg/l 0.01 mg/l | |
COD | 0.0 ... 800.0 mg/l 0.1 mg/l | 0.0 ... 800.0 mg/l 0.1 mg/l | |
TOC | 0.0 ... 500.0 mg/l 0.1 mg/l | 0.0 ... 500.0 mg/l 0.1 mg/l | |
DOC | 0.0 ... 500.0 mg/l 0.1 mg/l | 0.0 ... 500.0 mg/l 0.1 mg/l | |
BOD | 0.0 ... 500.0 mg/l 0.1 mg/l | 0.0 ... 500.0 mg/l 0.1 mg/l | |
SAC254 total | 0.0 ... 600.0 1/m 0.1 1/m | 0.0 ... 600.0 1/m 0.1 1/m | |
SAC254 dissolv | 0.0 ... 600.0 1/m 0.1 1/m | 0.0 ... 600.0 1/m 0.1 1/m | |
UVT254 total* | 0.0 ... 100.0 % 0.1 % | 0.0 ... 100.0 % 0.1 % | |
UVT254 dissolv* | 0.0 ... 100.0 % 0.1 % | 0.0 ... 100.0 % 0.1 % | |
TSS | 0.0 ... 900.0 mg/l 0.1 mg/l | ||
Flow rate | ≤ 3 m/s | ||
Pressure Resistance | Maximum 1 bar (incl. sensor connection cable) | ||
Electrical connections | 2-wire shield cable with quick fastener to sensor | ||
Electromagnetic Compatibility | EN 61326, Class B, FCC Class A | ||
Certifications | CE | ||
Mechanical | Housing: Titan Grade 2, PEEK | ||
Weight (without cable) | Approx. 8.82 lb (4 kg) | ||
Warranty | 2 years for defects in quality |
Model | NiCaVis® 705 IQ | NiCaVis® 705 IQ TS | |
Order No. | 481052 | 481053 | |
* The UVT-254 value is standardized to 10 mm gap width. | |||
Measuring method | Spectral Measurement in the UV-VIS Range (200 – 720 nm) | ||
Measuring gap | 5 mm | ||
Application (optimized for) | Municipal wastewater: | Municipal wastewater: | |
Measuring range and Resolution | Effluent: | Effluent: | |
NO3 | 0.0 ... 250.0 mg/l 0.1 mg/l | 0.0 ... 250.0 mg/l 0.1 mg/l | |
NO3-N | 0.00 ... 50.00 mg/l 0.01 mg/l | 0.00 ... 50.00 mg/l 0.01 mg/l | |
COD | 0.0 ... 800.0 mg/l 0.1 mg/l | 0.0 ... 800.0 mg/l 0.1 mg/l | |
TOC | 0.0 ... 500.0 mg/l 0.1 mg/l | 0.0 ... 500.0 mg/l 0.1 mg/l | |
DOC | 0.0 ... 500.0 mg/l 0.1 mg/l | 0.0 ... 500.0 mg/l 0.1 mg/l | |
BOD | 0.0 ... 500.0 mg/l 0.1 mg/l | 0.0 ... 500.0 mg/l 0.1 mg/l | |
SAC254 total | 0.0 ... 600.0 1/m 0.1 1/m | 0.0 ... 600.0 1/m 0.1 1/m | |
SAC254 dissolv | 0.0 ... 600.0 1/m 0.1 1/m | 0.0 ... 600.0 1/m 0.1 1/m | |
UVT254 total* | 0.0 ... 100.0 % 0.1 % | 0.0 ... 100.0 % 0.1 % | |
UVT254 dissolv* | 0.0 ... 100.0 % 0.1 % | 0.0 ... 100.0 % 0.1 % | |
TSS | 0.0 ... 900.0 mg/l 0.1 mg/l | ||
Flow rate | ≤ 3 m/s | ||
Pressure Resistance | Maximum 1 bar (incl. sensor connection cable) | ||
Electrical connections | 2-wire shield cable with quick fastener to sensor | ||
Electromagnetic Compatibility | EN 61326, Class B, FCC Class A | ||
Certifications | CE | ||
Mechanical | Housing: Titan Grade 2, PEEK | ||
Weight (without cable) | Approx. 8.82 lb (4 kg) | ||
Warranty | 2 years for defects in quality |
Model | NiCaVis® 705 IQ | NiCaVis® 705 IQ TS | |
Order No. | 481052 | 481053 | |
* The UVT-254 value is standardized to 10 mm gap width. | |||
Measuring method | Spectral Measurement in the UV-VIS Range (200 – 720 nm) | ||
Measuring gap | 5 mm | ||
Application (optimized for) | Municipal wastewater: | Municipal wastewater: | |
Measuring range and Resolution | Effluent: | Effluent: | |
NO3 | 0.0 ... 250.0 mg/l 0.1 mg/l | 0.0 ... 250.0 mg/l 0.1 mg/l | |
NO3-N | 0.00 ... 50.00 mg/l 0.01 mg/l | 0.00 ... 50.00 mg/l 0.01 mg/l | |
COD | 0.0 ... 800.0 mg/l 0.1 mg/l | 0.0 ... 800.0 mg/l 0.1 mg/l | |
TOC | 0.0 ... 500.0 mg/l 0.1 mg/l | 0.0 ... 500.0 mg/l 0.1 mg/l | |
DOC | 0.0 ... 500.0 mg/l 0.1 mg/l | 0.0 ... 500.0 mg/l 0.1 mg/l | |
BOD | 0.0 ... 500.0 mg/l 0.1 mg/l | 0.0 ... 500.0 mg/l 0.1 mg/l | |
SAC254 total | 0.0 ... 600.0 1/m 0.1 1/m | 0.0 ... 600.0 1/m 0.1 1/m | |
SAC254 dissolv | 0.0 ... 600.0 1/m 0.1 1/m | 0.0 ... 600.0 1/m 0.1 1/m | |
UVT254 total* | 0.0 ... 100.0 % 0.1 % | 0.0 ... 100.0 % 0.1 % | |
UVT254 dissolv* | 0.0 ... 100.0 % 0.1 % | 0.0 ... 100.0 % 0.1 % | |
TSS | 0.0 ... 900.0 mg/l 0.1 mg/l | ||
Flow rate | ≤ 3 m/s | ||
Pressure Resistance | Maximum 1 bar (incl. sensor connection cable) | ||
Electrical connections | 2-wire shield cable with quick fastener to sensor | ||
Electromagnetic Compatibility | EN 61326, Class B, FCC Class A | ||
Certifications | CE | ||
Mechanical | Housing: Titan Grade 2, PEEK | ||
Weight (without cable) | Approx. 8.82 lb (4 kg) Reviews (0) :Get specific details about this product from customers who own it. |