Automatic titrator Flash has been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations.
Up to two automatic burettes for titrant delivery and three peristaltic pumps can be installed. Automatic pH, acidity and SO2 analyses are made easy and simple.
Both a single analysis stand
and 16 or 35 positions autosamplers can be connected to Flash.
The instrument has been designed to optimize the sample auto-level analysis procedure speeding up the whole preparation. The optional degassing system ensures a complete automatic analysis procedure with no external sample pre-tratment needed.
Its new design features light weight and small footprint.
Dimensions dxlxh
294x215x308mm
Compact
Flash is a compact-modular
instrument and can be both upgraded and configutated to satisfy the
ever-changing laboratory needs
Easy to use
The colored touchscreen
display guides the user in each programming, analysis and data interpretation
phase;
On Line Graphics
During the titration
process, a graph giving the analysis trend is displayed in real time.
SPECIFIC PROGRAMS ONLY FOR
OENOLOGICAL ANALYSES
pH and total acidity:
performed with a pH electrode on tel quel sample (editable pH end-point
titration)
Free, total and combined
SO2: performed with double platinum electrode on tel quel sample (ripper
method)
pH calibration and reagents
standardization: optional calibration with several buffers (e.g. 7/3pH)
AUTOMATIC BURETTES
Up to 2 burettes can be
installed:
burette equipped with 12.000
high-definition stepper motor
10ml clear glass syringe and
tip made of interchangeable PTFE
Three-way valve
(titrant/cleaning reactant suction, titrant delivery, syringe) made of
anti-corrosive material
PUMPS
Very often a titration
process requires addition of auxiliary reagents such as acid for acidifying,
water for diluting, etc...
With up to a maximum of 3
peristaltic pumps, operated together or separately, every phase of the
titration process can be made totally automatic.
Delivery: 1ml/sec
Internal tube: neoprene
External tube: PVC and PTFE
Accessories
Printer; Single analyses
stand; Sampler: 16 and 35 positions; Automatic degasser; Software for data management
on external PC
Internal memory: 50
analyses, 10 calibrations; 30 methods
Data export: date, hour,
operator ID, sample ID, method, result, titrant volume
pH calibration: a) 1 buffer
calibration (7) b) 2 buffers calibration (7, 4 or 10) c) Theorical (Nernst
equation) d) Oenologi-cal: 2 buffers calibration (7, 3), Temperature
compensation with pt100 probe during pH Calibration; Buffer auto-recognize;
Refusal defective electrodes; Notice expired calibration